Fluoride Removal In A Fixed Bed Packed With Granular Calcite
论文类型 | 技术与工程 | 发表日期 | 2006-03-01 |
来源 | 中国水网 | ||
作者 | 杨敏,TAKAYUKI,HASHIMOT | ||
关键词 | fluoride removal calcite replacement wastewater treatment | ||
摘要 | A fixed bed reactor filled with calcite particles (mean strokes diameter, 0.20 mm) was constructed and the reactor was used to treat synthetic wastewater containing HF, NaF, NH4F or Na2SiF6 under various conditions. Calcium ions (Ca2+) were found to exist |
相关推荐
- Nitrifying Population Optimization in Municipal Saline Wastewater Treatment
- Separation of Sulfur/Gasoline Mixture with Polydimethylsiloxane/Polyetherimide Composite Membranes by Pervaporation
- Enhanced Biological Nutrients Removal in Modified Step-feed Anaerobic/Anoxic/Oxic Process
- Characterization of the start-up period of single-step autotrophic nitrogen removal in a sequencing batch reactor
- RES EARCH ON MEMBRANE B IOREACTOR TREATING DOMES TIC WAS TEWATER AND RELATED MECHAN ISMS
- A_O工艺与分段进水两种生物脱氮工艺的比较研究_英文
论文搜索
月热点论文
论文投稿
很多时候您的文章总是无缘变成铅字。研究做到关键时,试验有了起色时,是不是想和同行探讨一下,工作中有了心得,您是不是很想与人分享,那么不要只是默默工作了,写下来吧!投稿时,请以附件形式发至 paper@h2o-china.com ,请注明论文投稿。一旦采用,我们会为您增加100枚金币。